Technical specifications for Goldgear GG61F5
Power range
BB61F5 1-300 kW 400V
0.0-22 kW 200V
Main conection
Input Voltage [400 V] 304-460 V [+ - 20%]
[200 V]176-266 V [+ - 20%]
Input Frequency 40 - 66 Hz
Motor conection
Output Voltage 0 - Uin
Continuous output current V/F 150 % 1 min, Vector180% 1min
Output Frequency 0 - 300 Hz
Frequency Resolution 0.01 Hz
Control Characteristics
Control Method V/F control,Vector control[VEC],Sensorless Vector Control[SSL]
Frequency res.Analog Input Resolution 12 Bit,accuracy +/- 1 %
Frequency ref, Penel ref. Resolution 0.01 Hz
Switching Frequency 1-15 kHz
Field weakening 50 - 600 Hz
Breaking torque without break resistor 30 % DC brake
Torque Response 50 microSEC for Vector Control
Protective function
Over current protection Yes
Over voltage protection Trip limit 1.2 x Uin
Under voltage protection Trip limit 0.8 x Uin
Motor overload protection Electronic thermal overload relay
Motor stall protection Yes
Unit over temperature protection Yes
Current limit protection(Hardware/Software) Yes
Control connection
Analog Voltage 0 - 10 V, +/- 0 -10 V,R = 1-5kOHM
Analog Current 4-0 mA,R1- 250 OHM,differential
Digital input 5 pcs,(Programable)
Auxilary voltage output 10 VDC max 100mA
Analog output 0-10 V,x2 Channel(Programmable)
Relay output 2 pcs/300 VDC, 250 VAC
Digital output 2 pcs/open collector input
Enclosure
GG61F5
         Type           
Cooling air flow requierment
Normianl ratings
NO overload used
Light overload used
Heavy duty use
Noise level
Heat dissipation
Air flow
I cont.max
A
i max
A
P constant
kW
In
A

Pn
 I nd
A
P nd
kW

Frame size

dBA

W

m3/h
Three phase supply voltage 380,400,or 415 V,The power rating are valid at nominal voltage(400V)
GG61F5-001-4
2.8
3.44
0.75
2.6
0.75
2.2
0.37
R0
60
95
45
GG61F5-002-4
3.9
4.6
1.5
3.6
1.5
3.0
0.75
R0
60
105
45
GG61F5-003-4
5.2
6.2
2.2
4.8
2.2
3.8
1.5
R0
60
125
45
GG61F5-005-4
7.6
9
3.7
7.0
3.7
6
2.2
R1
62
165
70
GG61F5-008-4
12
14
5.5
11
5.5
9
3.7
R1
62
210
80
GG61F5-010-4
15.5
18
7.5
14
7.5
12
5.5
R1
62
260
80
GG61F5-015-4
23
27
11
21
11
18
7.5
R2
62
345
110
GG61F5-020-4
29
34
15
26
15
22
11
R2
62
430
110
GG61F5-025-5
37.5
44
18.5
34
18.5
27
15
R2
62
480
110
GG61F5-030-4
41
48
22
38
22
32
18.5
R2
62
535
110
GG61F5-040-4
56
65
30
53
30
39
22
R3
62
620
110
GG61F5-050-4
68
80
37
64
37
48
30
R3
65
800
180
GG61F5-060-4
82
96
45
78
45
60
37
R3
65
995
180
GG61F5-075-4
110
128
55
107
55
80
45
R4
65
1200
400
GG61F5-100-4
140
165
75
137
75
100
55
R4
65
1440
400
GG61F5-125-4
165
195
90
161
90
120
75
R5
65
1940
400
GG61F5-150-4
190
224
110
185
110
150
90
R5
71
2310
620
GG61F5-200-4
256
302
150
250
150
210
110
R5
71
3800
620
GG61F5-250-4
321
378
180
315
180
290
150
R5
72
4400
1200
GG61F5-300-4
386
454
220
380
220
320
180
R6
72
5000
1200
GG61F5-350-4
425
500
260
420
260
380
220
R6
72
6180
1200
         Type           
Cooling air flow requierment
Normianl ratings
NO overload used
Light overload used
Heavy duty use
Noise level
Heat dissipation
Air flow
I cont.max
A
i max
A
P constant
kW
In
A

Pn

 I nd
A
P nd
kW

Frame size

dBA

W

m3/h
Single phase or three phase supply voltage 200,220,or 230 V,The power rating are valid at nominal voltage(200V)
GG61F5-0.5-2
2.75
3.2
0.37
2.6
0.37
2.1
0.2
R0
35
85
25
GG61F5-001-2
4.3
5
0.75
4.0
0.75
3.8
0.37
R0
35
115
25
GG61F5-002-2
6.8
8
1.5
6.2
1.5
5.8
0.75
R0
35
150
25
GG61F5-003-2
9.5
11
2.2
9.1
2.2
7
1.5
R1
35
200
25
GG61F5-005-2
14.5
17
3.7
14
3.7
11
2.2
R1
62
250
80
GG61F5-008-2
22
25
5.5
21
5.5
16
3.7
R1
62
360
80
GG61F5-010-2
28
33
7.5
27
7.5
21.5
5.5
R2
62
430
80
GG61F5-015-2
41
48
11
40
11
32
7.5
R2
62
535
80
GG61F5-020-2
52
60
15
50
15
37
11
R2
65
600
180
GG61F5-025-2
67
78
18.5
65
18.5
46
15
R3
65
790
180
GG61F5-030-2
72
84
22
70
22
53
18.5
R3
65
820
180

Type
Ip21
H
mm
W
mm
D
mm
R0
165
110
165
R1
360
215
180
R2
470
265
255
R3
665
320
265
R4
905
460
340
R5
1400
530
450
R6
1800
790
600
*Weights are for the basic configuration with switch fuse,but without contactor and other option.
Nomianl Rating : Icont.max : rated current available
                  continuously  without overloadability at
                  40 degree c
Imax : maximum output current.Available for 10 s at
           start,ohterwise as long as allowed by drive
           temperature.
           Note : max.motor shaft power is 150% Pnd

Typical Rating : No-overload use
Pcont.max : typical motor power in no-overload use.

Lignt-overload use
In : continuous current allowing 110% In for 1 min/5min at 40 Degree C
Pn : typical motorpower in lignt-overload use

Heavy-duty Id : continuous current allowing 150 % Ind for 1 min/5 at 40 Degree C Pnd : typical motorpower in heavy-duty use current rating are the same
         regradless of the supply voltage within ont voltage range The rating
         apply in 40 degree C ambient temperature.In lower temperatures the
        ratings are higher(except Imax)
BASIC SCHEMATIC DIAGRAM

DIGITAL AUTOMATIC EVACUATION SYSTEM
use for elevator system,in the elavator of main power failure or building is fire
- Digital DSP Microprocessor
- if the elevator stop between floors,or with door close
- the device automatically turn-on and run to the nearest floor and
   reopening the door.
- 2 line x 16 Character. LCD operator
- Use the microprocessor control setting program and digital asjust
   replace to analog adjust
- Have Display show statuss of useand battery
- Easy installation ,Easy Setting and small size
- 48 V battery,Sealed Lead Time without mainenance
- Economy cost

SPECIFICATION
  •    Traction motor
170/220/380/415 V     3 Phase 50/60 Hz
  •    Break supply

60/70/110/180/220/240 VDC(max 200 watt)

  •    Door Motor
AC or DC programable for DC drive or inverter drive 60 70 110 180 240 programmable(max 200 watt)
  •    Floor detect sensor supply
24 VDC
  •    Car lamp supply

220 VAC (max 100 watt)

  •    Safety switch
Over run safety programable NO/NC
Safety 1 programmable NO/NC
Safety 2 programmable NO/NC
  •    Floor detection
Can be select NO/NC programmable or common
  •    Door open limit switch
Door open limit switch can be select NO/NC programable
  •    Signal for open door motor
NO contact can be set the operate time of contact
  •    Battery
Sealed lead type battery
  •    Display 
"LCD" 2 line 16 charactor and status lcd display
  •    Charger
closeloop current Charger Control
  •    Protection of equipment supply
Short circuit supply output protection
And fuse protection for carlamp / 24 VDC / door motor
  •    Detection system
3 phase detection
  •    Ambient temperature
-10 to +50 degree C
  •    Ambient humidity
90 % RH or less(no conden sation)
  •    Attitude and vibration
Max 100 m above sealevel max 5.9m (0.6g)
Protection Specification
LCD display mode trip
  • Over current (Traction motor over current)
  • Over voltage (Battery over voltage)
  • Under voltage (Battery under voltage)
  • Safety 1 open
  • Safety 2 open
  • Safety over run open
  • Charger fail ( battery loss)

FUNCTION TABLE OF AUTOMATIC EVACUATION SYSTEM
 
FAC.SET
DESCRIPTION
DATA
Output frequency
04.0
  Output frequency for traction motor
0 - 50 Hz
Boost voltage
03
  Troque boost of traction motor
0 - 10%
Accel time
05
  Accellerate time of traction motor
0 - 9999
Motor rated freq.
50
  Base frequency of traction motor
0 - 5
Motor rated volt
380
  Base voltage of traction motor
0 - 380
Mech.break volt
110
  Supply for machine break
60 - 240
Door operate type
AC
  Door operate control type
AC / DC
Door operated volt
110
  Supply for door operate control
60 - 240
Floor detect cont.
NO
  Type of floor detect sensor contact
NO /NC
Door open cont.
NO
  Type of door open limit contact
NO /NC
Over run cont.
NO
  Type of over run safety limit contact
NO /NC
Safety switch#1
NO
  Type of safety switch 1 contact
NO /NC
Safety switch#2
NO
  Type of safety switch 2 contact
NO /NC
Max operate time
220
  Max operate time of aes
0 - 9999
Start time delay
05
  Delay time before aes operate
0 - 9999
FL.detect delay
00
  Delay time to stop traction after floor detected
0 - 9999
Door operate time
10
  Time for NO contact to door open control
0 - 9999
Delay to finish
10
  Delay timr after door open O.K.
0 - 9999
Factory setting
NO
  Set the data to factory setting sata
Y / N
Program lock
NO
  Program lock
Y / N
Direction search
YES
  Select direction searching or not
Y / N
Max amp allowed
15.0
  Set the rated current for check direction to light wight  
0 - 9999
Selection Guide
Model
MOTOR RATINGI
BATTERY
170 V
220 V
380 V
415 V
A
kW(HP)
kW(HP)
kW(HP)
kW(HP)
GG-AES 010
3(4)
4(5.5)
7.5(10)
8.5(12)
18
4 BATT 48 V (12v -12Ah x 4)
GG-AES 015
4(5)
6.38(8.5)
11(15)
12(16)
25
4 BATT 48 V (12v -7Ah x 4)
GG-AES 020
5.5(7.5)
7.5(10)
15(20)
17(23)
34
5 BATT 60 V (12v -7Ah x 5)
GG-AES 025
7.5(10)
10.5(14)
18(25)
20(27)
44
5 BATT 60 V (12v -7Ah x 5)
GG-AES 030
8.5(12)
12.6(17)
22(30)
24(32)
50
5 BATT 60 V (12v -7Ah x 5)
GG-AES 040
11(15)
18(25)
30(40)
29(38)
70
5 BATT 60 V (12v -12Ah x 5)
DIMENSION    
kW
1.5 kW - 15 kW
18.5 kW - 30 kW
W
420 mm.
510 mm.
H
700 mm.
900 mm.
D
230 mm.
280 mm.
BASIC SCHIMATIC DIAGRAM